HID (PROXPOINT PLUS) |
HID (MINIPROX) |
Read Range: ProxCard II
Proximity & Mifare |
Upto 3” (7.6cm)
Upto 2.5” (6.35cm) |
Upto 5.5” (14cm)
Upto 5” (12.5cm) |
Size (Inches) |
3.13x1.72x0.66 |
6.0x1.7x1.0 |
Frequency |
125Khz |
Weight |
75 gms |
99 gms (with terminal strip): 108gms (with pigtail/ hazard location) |
Current Draw: Average
: Peak |
30mA
75mA |
30mA (5VDC): 20mA (12VDC)
110ma (5VDC): 110mA (12VDC) |
Operating Temperature |
-30°C to +65°C |
Operating Humidity |
0-95% relative humidity non condensing |
Power Supply |
5-16VDC. Linear power supplies are recommended |
Application in haz. Loc. |
No. |
Designed to mount on junction box. (Rated for use in haz. Loc.) |
Cable Distance |
Weigand or Clock-and-data interface:500 feet (150m) Recommended cable is ALPHA 1295 (22 AWG) 5 conductor stranded with overall shield or equivalent |
Weigand interface:500 feet (150m) Clock-and-data interface: 50 feet (15m) Recommended cable is ALPHA 1295 (22AWG) 5 conductor minimum stranded with overall shield or equivalent. Additional conductors may be required for LED or beeper control. |
Certifications |
Ul, CE, FCC, EU and CB Scheme Electrical Safety, EN 300 330-SRD and ETS 300 683-EMC for MINIPROX with haz. Loc. Junction box: Canada / UL 1604 Class I, Div 2 groups. |